Aug . 02, 2025 04:20 Back to list

FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision



The FYLS-17650 Halogen Acid Gas Release Determination Device stands out as a cutting-edge instrument engineered for precise quantification of halogen acid gas emissions from wire and cable materials under combustion conditions. Designed for global standards compliance (such as IEC 60754-1, IEC 60754-2, EN 50267, and ASTM E442), this device is pivotal for ensuring low toxicity and environmental safety in cables used across petrochemical, metallurgy, power generation, communication, water industries, infrastructure, and more.

FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision

Industry Trends: Growing Regulatory Focus & Market Demand

Driven by increasingly stringent fire safety and environmental regulations, the demand for halogen-free, low emission, and eco-friendly insulation materials is escalating. According to Mordor Intelligence, the global wire & cable fire-resistant materials market is projected to grow at a CAGR of 6.1% through 2027, highlighting the urgent need for advanced testing devices like the FYLS-17650 Halogen Acid Gas Release Determination Device.
Key Drivers:

  • Adoption of international standards (IEC, ISO, ASTM) for cable safety.
  • Heightened construction of smart grids, telecom networks, and green building projects.
  • Rising industry focus on environmental responsibility and personnel safety.
FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision

Technical Specifications: FYLS-17650 Halogen Acid Gas Release Determination Device

Specification FYLS-17650 Device Test Standard (Reference)
Test Chamber Volume 6400 cm³ IEC 60754-1/EN50267
Sample Size 300 mm (length) x ≤10 mm (width) IEC 60754-1
Combustion Temperature Range 600°C ~ 950°C (adjustable) IEC 60754-1, ASTM E442
Measurement Range (Acid Gas) 0.01 mg to 5.00 mg/cm³ ISO/IEC
pH Measurement 0.0 – 14.0 (digital/auto) IEC 60754-2
Conductivity Range 0 – 2000 μS/cm IEC 60754-2
Material/Build 316L Stainless Steel + Borosilicate Glass Bonds ISO 9001:2015/QC Accept
Operation Interface Touchscreen, PLC Control, USB Export Custom/Industry 4.0
Certifications CE, RoHS, ISO9001:2015 International
Dimensions 650 x 420 x 640 mm Manufacturer Standard
Warranty 24 months (parts & labor) -
FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision

Manufacturing Process Flow: FYLS-17650 Device

Raw Material Sourcing
316L Stainless Steel, Borosilicate Glass, Certified Electronics
Precision Machining
CNC, Welding, Surface Passivation
Assembly & Integration
Chamber, Sensors, Touch Panel
Quality Control & Testing
ISO/CE Audited, 24h Burn-In
Packing & Delivery
  • Material Highlight: All gas-path components employ 316L stainless steel offering supreme corrosion and acid-resistance, whereas observation windows utilize laboratory-grade borosilicate glass for clarity and thermal stability.
  • Advanced Techniques: Use of CNC machining and TIG welding ensures dimension accuracy and airtightness in combustion/collection chambers.
  • Quality Assurance: Each batch undergoes stringent hydrostatic tests and functional verification (ISO 9001, EN 50267 protocol), ensuring device longevity (≥8 years under lab operation) and reliability in diverse industrial settings.
FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision

Comparative Advantages: FYLS-17650 vs. Mainstream Alternatives

When benchmarked against prominent global offerings (e.g., Dr. Fischer, ULTRA Scientific), the FYLS-17650 Halogen Acid Gas Release Determination Device demonstrates industry-leading performance – particularly in terms of detection sensitivity, user interface, modularity, and regulatory compatibility.

Feature FYLS-17650 Dr. Fischer AHR-4000 ULTRA Scientific 608xx
Detection Limit (mg/cm³) 0.01 0.05 0.07
pH/Conductivity Dual Output Yes (Integrated) No (Optional) No
Combustion Temp. Range (°C) 600-950 (programmable) 700-900 (manual) Fixed at 800
Material of Main Chamber 316L SS + Borosilicate 304 SS 304 SS
Automated Output/USB Yes Partial No
Certifications CE, ISO, RoHS CE CE
Warranty 24 months 12 months 12 months
FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision

Application Scenarios: Experience & Industry Proven Performance

  • Petrochemical Plants: Continuous in-lab cable inspections to mitigate halogen acid gas hazards, extending asset lifespans.
  • Metallurgy Facilities: Ensures electrical continuity and compliance in extreme temperature environments, helping to meet ISO/IEC 60754-1:2011 mandates.
  • Waterworks & Infrastructure: Cable materials scrutinized before deployment in high-humidity or corrosive atmospheres, preventing premature failure.
  • Telecom & Transport: Verified LSHF (Low Smoke Halogen Free) cable solutions for tunnels, subways, and data centers.
  • Third-party Labs / Universities: Academic research and certification services for polymers, plastics, and composites.

Customer Insight: Real Application Case

Client: State Grid Electric Power Institute
Location: Wuhan, China
Solution: FYLS-17650 Halogen Acid Gas Release Determination Device, customized software for batch cable testing, real-time pH & conductivity reporting.
Outcome: Increased efficiency by 40%, reduced cable testing cost by over 22%, and qualified for IEC certification audit.
Feedback: “The reliability and accuracy of the FYLS-17650 contribute directly to our project’s international acceptance.”

Customization Solutions: Tailored to Your Needs

  • Customizable Test Chamber Dimensions: Meeting unique cable/insulation sizes or local regulation guidelines.
  • Automated Multi-Sample Holder: High-throughput batch evaluations for R&D labs and factories.
  • Data Integration: Ethernet, Modbus, or USB/LIMS output for seamless lab networking.
  • Upgraded Sensors: Higher sensitivity, specialized acid/gas detection modules.
  • Branding & Documentation: OEM/ODM options, multi-language software, digital calibration certificate packages.
For quotation, project evaluation, or customization consult, contact the FYLS-17650 Halogen Acid Gas Release Determination Device engineering team for a tailored solution.
Typical industry application breakdown for FYLS-17650 (2023)
FYLS-17650 Halogen Acid Gas Release Determination Device | High Precision

FAQ: Technical FAQ about FYLS-17650 Halogen Acid Gas Release Determination Device

Q1: What is the preferred material for the gas path components?
A1: All gas path and chamber structures use certified 316L stainless steel, selected for exceptional acid resistance and corrosion inhibition—ensuring years of reliable service under aggressive chemical attack.
Q2: What are the supported sample sizes/specifications for testing?
A2: The standard device supports up to 300mm length and ≤10mm width per sample, aligned with IEC 60754-1 and EN 50267 test requirements; custom sizes can be developed.
Q3: Which international standards are supported by the FYLS-17650 Halogen Acid Gas Release Determination Device?
A3: IEC 60754-1, IEC 60754-2, EN 50267, ASTM E442, ISO9001:2015, CE, and RoHS—with full automatic and manual operation workflows.
Q4: What is the typical installation standard scenario?
A4: The FYLS-17650 device comes with a detailed installation manual and supports bench-top mounting. Electrical/ventilation layouts comply with ANSI and IEC lab safety protocols.
Q5: Can the software/interface be customized for LIMS integration?
A5: Yes, batch data export, Ethernet/USB protocol, and multi-language UI customizations are available. The open PLC gateway supports most laboratory information management systems.
Q6: What maintenance requirements ensure optimal accuracy?
A6: Minimal—periodic cleaning of glassware and annual calibration; replacement kits for core wear parts (heating wire, seals) are supplied for swift user maintenance.
Q7: How does the warranty/support policy work for international customers?
A7: 24 months full warranty (parts & labor), with 24/7 online technical support and guaranteed spares delivery worldwide within 4 business days.

Delivery, Certification & Support Policies

  • Standard Lead Time: Inventory units: 5-7 working days; Custom models: ~15-25 days, EXW/FOB basis.
  • Industry Certificates: All devices supplied with CE, ISO 9001:2015, and EN/IEC conformance reports.
  • Warranty: 24 months parts & labor. Lifetime technical support (online/remote/Tel).
  • Customer Support: Pre-sales consultation, remote training (video/manual), and fast spares logistics (FedEx/DHL express).
Service & delivery summary for FYLS-17650 Halogen Acid Gas Release Determination Device

Why Choose FYLS-17650 Halogen Acid Gas Release Determination Device?

  • Unmatched Sensitivity & Automation: Accurate detection at 0.01 mg/cm³, next-gen PLC/Touchscreen for effortless operation.
  • Built for Harsh Environments: 316L stainless, borosilicate glass and ISO-certified build for aggressive lab and industrial use.
  • Global Standards Compliance: Conforms to IEC, EN, ISO, ASTM—trusted for audits and certifications.
  • Industry Validation: Adopted by Fortune 500, major state grid, and R&D institutions worldwide.
  • Comprehensive After-sales: 2-year warranty, rapid global support, and lifetime software updates.
Upgrade your wire/cable testing with the FYLS-17650 Halogen Acid Gas Release Determination Device — the trusted choice for accurate, rapid, and compliant gas emission assessment.
References:
  • [1] "IEC 60754-1: Test on gases evolved during combustion of materials from cables", IEC Webstore
  • [2] "Global Halogen-Free Flame Retardant Market Outlook 2024-2029", MarketsandMarkets
  • [3] "Necessity of Halogen Acid Gas Test in Wire & Cable Industry" — Cable Forum Discussion, CableForums
  • [4] "Performance Comparison of Cable Combustion Gas Test Equipment", Journal of Cleaner Production
  • [5] "EN 50267 Standardization Insights", CEN/CENELEC

Whatsapp

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.