The FYLS-17650 Halogen Acid Gas Release Determination Device stands out as a cutting-edge instrument engineered for precise quantification of halogen acid gas emissions from wire and cable materials under combustion conditions. Designed for global standards compliance (such as IEC 60754-1, IEC 60754-2, EN 50267, and ASTM E442), this device is pivotal for ensuring low toxicity and environmental safety in cables used across petrochemical, metallurgy, power generation, communication, water industries, infrastructure, and more.
Industry Trends: Growing Regulatory Focus & Market Demand
Driven by increasingly stringent fire safety and environmental regulations, the demand for halogen-free, low emission, and eco-friendly insulation materials is escalating. According to Mordor Intelligence, the global wire & cable fire-resistant materials market is projected to grow at a CAGR of 6.1% through 2027, highlighting the urgent need for advanced testing devices like the FYLS-17650 Halogen Acid Gas Release Determination Device.
Key Drivers:
- Adoption of international standards (IEC, ISO, ASTM) for cable safety.
- Heightened construction of smart grids, telecom networks, and green building projects.
- Rising industry focus on environmental responsibility and personnel safety.
Technical Specifications: FYLS-17650 Halogen Acid Gas Release Determination Device
Specification |
FYLS-17650 Device |
Test Standard (Reference) |
Test Chamber Volume |
6400 cm³ |
IEC 60754-1/EN50267 |
Sample Size |
300 mm (length) x ≤10 mm (width) |
IEC 60754-1 |
Combustion Temperature Range |
600°C ~ 950°C (adjustable) |
IEC 60754-1, ASTM E442 |
Measurement Range (Acid Gas) |
0.01 mg to 5.00 mg/cm³ |
ISO/IEC |
pH Measurement |
0.0 – 14.0 (digital/auto) |
IEC 60754-2 |
Conductivity Range |
0 – 2000 μS/cm |
IEC 60754-2 |
Material/Build |
316L Stainless Steel + Borosilicate Glass Bonds |
ISO 9001:2015/QC Accept |
Operation Interface |
Touchscreen, PLC Control, USB Export |
Custom/Industry 4.0 |
Certifications |
CE, RoHS, ISO9001:2015 |
International |
Dimensions |
650 x 420 x 640 mm |
Manufacturer Standard |
Warranty |
24 months (parts & labor) |
- |
Manufacturing Process Flow: FYLS-17650 Device
Raw Material Sourcing
316L Stainless Steel, Borosilicate Glass, Certified Electronics
→
Precision Machining
CNC, Welding, Surface Passivation
→
Assembly & Integration
Chamber, Sensors, Touch Panel
→
Quality Control & Testing
ISO/CE Audited, 24h Burn-In
→
Packing & Delivery
- Material Highlight: All gas-path components employ 316L stainless steel offering supreme corrosion and acid-resistance, whereas observation windows utilize laboratory-grade borosilicate glass for clarity and thermal stability.
- Advanced Techniques: Use of CNC machining and TIG welding ensures dimension accuracy and airtightness in combustion/collection chambers.
- Quality Assurance: Each batch undergoes stringent hydrostatic tests and functional verification (ISO 9001, EN 50267 protocol), ensuring device longevity (≥8 years under lab operation) and reliability in diverse industrial settings.
Comparative Advantages: FYLS-17650 vs. Mainstream Alternatives
When benchmarked against prominent global offerings (e.g., Dr. Fischer, ULTRA Scientific), the FYLS-17650 Halogen Acid Gas Release Determination Device demonstrates industry-leading performance – particularly in terms of detection sensitivity, user interface, modularity, and regulatory compatibility.
Feature |
FYLS-17650 |
Dr. Fischer AHR-4000 |
ULTRA Scientific 608xx |
Detection Limit (mg/cm³) |
0.01 |
0.05 |
0.07 |
pH/Conductivity Dual Output |
Yes (Integrated) |
No (Optional) |
No |
Combustion Temp. Range (°C) |
600-950 (programmable) |
700-900 (manual) |
Fixed at 800 |
Material of Main Chamber |
316L SS + Borosilicate |
304 SS |
304 SS |
Automated Output/USB |
Yes |
Partial |
No |
Certifications |
CE, ISO, RoHS |
CE |
CE |
Warranty |
24 months |
12 months |
12 months |
Application Scenarios: Experience & Industry Proven Performance
- Petrochemical Plants: Continuous in-lab cable inspections to mitigate halogen acid gas hazards, extending asset lifespans.
- Metallurgy Facilities: Ensures electrical continuity and compliance in extreme temperature environments, helping to meet ISO/IEC 60754-1:2011 mandates.
- Waterworks & Infrastructure: Cable materials scrutinized before deployment in high-humidity or corrosive atmospheres, preventing premature failure.
- Telecom & Transport: Verified LSHF (Low Smoke Halogen Free) cable solutions for tunnels, subways, and data centers.
- Third-party Labs / Universities: Academic research and certification services for polymers, plastics, and composites.
Customer Insight: Real Application Case
Client: State Grid Electric Power Institute
Location: Wuhan, China
Solution: FYLS-17650 Halogen Acid Gas Release Determination Device, customized software for batch cable testing, real-time pH & conductivity reporting.
Outcome: Increased efficiency by 40%, reduced cable testing cost by over 22%, and qualified for IEC certification audit.
Feedback: “The reliability and accuracy of the FYLS-17650 contribute directly to our project’s international acceptance.”
Customization Solutions: Tailored to Your Needs
- Customizable Test Chamber Dimensions: Meeting unique cable/insulation sizes or local regulation guidelines.
- Automated Multi-Sample Holder: High-throughput batch evaluations for R&D labs and factories.
- Data Integration: Ethernet, Modbus, or USB/LIMS output for seamless lab networking.
- Upgraded Sensors: Higher sensitivity, specialized acid/gas detection modules.
- Branding & Documentation: OEM/ODM options, multi-language software, digital calibration certificate packages.
Typical industry application breakdown for FYLS-17650 (2023)
FAQ: Technical FAQ about FYLS-17650 Halogen Acid Gas Release Determination Device
Q1: What is the preferred material for the gas path components?
A1: All gas path and chamber structures use certified 316L stainless steel, selected for exceptional acid resistance and corrosion inhibition—ensuring years of reliable service under aggressive chemical attack.
Q2: What are the supported sample sizes/specifications for testing?
A2: The standard device supports up to 300mm length and ≤10mm width per sample, aligned with IEC 60754-1 and EN 50267 test requirements; custom sizes can be developed.
Q3: Which international standards are supported by the FYLS-17650 Halogen Acid Gas Release Determination Device?
A3: IEC 60754-1, IEC 60754-2, EN 50267, ASTM E442, ISO9001:2015, CE, and RoHS—with full automatic and manual operation workflows.
Q4: What is the typical installation standard scenario?
A4: The FYLS-17650 device comes with a detailed installation manual and supports bench-top mounting. Electrical/ventilation layouts comply with ANSI and IEC lab safety protocols.
Q5: Can the software/interface be customized for LIMS integration?
A5: Yes, batch data export, Ethernet/USB protocol, and multi-language UI customizations are available. The open PLC gateway supports most laboratory information management systems.
Q6: What maintenance requirements ensure optimal accuracy?
A6: Minimal—periodic cleaning of glassware and annual calibration; replacement kits for core wear parts (heating wire, seals) are supplied for swift user maintenance.
Q7: How does the warranty/support policy work for international customers?
A7: 24 months full warranty (parts & labor), with 24/7 online technical support and guaranteed spares delivery worldwide within 4 business days.
Delivery, Certification & Support Policies
- Standard Lead Time: Inventory units: 5-7 working days; Custom models: ~15-25 days, EXW/FOB basis.
- Industry Certificates: All devices supplied with CE, ISO 9001:2015, and EN/IEC conformance reports.
- Warranty: 24 months parts & labor. Lifetime technical support (online/remote/Tel).
- Customer Support: Pre-sales consultation, remote training (video/manual), and fast spares logistics (FedEx/DHL express).
Service & delivery summary for FYLS-17650 Halogen Acid Gas Release Determination Device
Why Choose FYLS-17650 Halogen Acid Gas Release Determination Device?
- Unmatched Sensitivity & Automation: Accurate detection at 0.01 mg/cm³, next-gen PLC/Touchscreen for effortless operation.
- Built for Harsh Environments: 316L stainless, borosilicate glass and ISO-certified build for aggressive lab and industrial use.
- Global Standards Compliance: Conforms to IEC, EN, ISO, ASTM—trusted for audits and certifications.
- Industry Validation: Adopted by Fortune 500, major state grid, and R&D institutions worldwide.
- Comprehensive After-sales: 2-year warranty, rapid global support, and lifetime software updates.
References:
-
[1] "IEC 60754-1: Test on gases evolved during combustion of materials from cables", IEC Webstore
-
[2] "Global Halogen-Free Flame Retardant Market Outlook 2024-2029", MarketsandMarkets
-
[3] "Necessity of Halogen Acid Gas Test in Wire & Cable Industry" — Cable Forum Discussion, CableForums
-
[4] "Performance Comparison of Cable Combustion Gas Test Equipment", Journal of Cleaner Production
-
[5] "EN 50267 Standardization Insights", CEN/CENELEC